mode of transmission | Multi mode |
---|
clock frequency | 266 MHz |
---|
number of slots | 16 10 4 2 6 |
---|
number of racks | 2 - local rack(s) |
---|
number of distributed I/O station | 63 station(s) - 1 rack(s) - 3 Modbus Plus network(s) |
---|
number of remote I/O station | 31 - 2 rack(s) per S908 remote I/O 31 - 2 rack(s) per ethernet Quantum remote I/O 16 - 2 rack(s) per ethernet X80 remote I/O |
---|
discrete I/O number | 31744 inputs, 31744 outputs - remote 8000 inputs, 8000 outputs - distributed - per network Modbus Plus Unlimited (31 drops of 28 slots max) - ethernet remote I/O 0 - local - forbidden in Hot Standby application |
---|
analogue I/O number | 500 inputs, 500 outputs - distributed - per network Modbus Plus Unlimited (31 drops of 28 slots max) - ethernet remote I/O 1984 inputs,1984 outputs - remote 0 - local - forbidden in Hot Standby application |
---|
application specific I/O | Counter High-speed interrupt inputs Accurate time stamping Serial link |
---|
communication service | Ethernet router |
---|
number of optional modules | 6 (Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max) |
---|
maximum number of connections | 1 USB 2 AS-Interface - distributed 4 AS-Interface - remote 6 Ethernet TCP/IP - local 6 Modbus Plus - local 6 Profibus DP - local 1 Modbus (RS232/485 Modbus/ASCII) |
---|
integrated connection type | 1 Modbus Plus with 1 Modbus with 1 USB with 1 optic fibre with Hot Standby |
---|
checks | Hot standby Process control |
---|
memory description | Expandable 7168 kB - program with PCMCIA card Expandable 8 MB - file storage with PCMCIA card Internal RAM 1024 kB - 512 kB for data |
---|
switch function | Key switch memory port on/off |
---|
application structure | 1 periodic fast task - forbidden in Hot Standby application 128 I/O interrupt tasks - forbidden in Hot Standby application 128 interrupt tasks - forbidden in Hot Standby application 32 timer interrupt tasks - forbidden in Hot Standby application 4 auxiliary tasks - forbidden in Hot Standby application 1 cyclic/periodic master task - |
---|
number of instructions per ms | 10.28 Kinst/ms 100 % Boolean 10.07 Kinst/ms 65 % Boolean and 35 % numerical |
---|
system overhead | 0.2 ms for fast task 1 ms for master task |
---|
bus current requirement | 2500 mA |
---|
local signalling | 1 LED (green) for Ethernet activity (COM) 1 LED (red) for Ethernet collision |
---|
electrical connection | 1 female connector, connector type: SUB-D 9 for connecting to the Modbus Plus network 1 connector, connector type: RJ45 for connecting Modbus bus 1 connector, connector type: MT-RJ (multimode fiber optic) for interconnecting primary and secondary PLCs up to 4 km |
---|